TGH-SCr Hexavalent chromium/chromium total water quality on-line automatic monitor

Page view

TGH-SCr Hexavalent chromium/chromium total water quality on-line automatic monitor

没有此类产品
Description

Instrument is introduced
TGH - SCr hexavalent chromium/chromium total water quality on-line automatic monitor using diphenyl 2 hydrazine spectral colorimetric method to determine carbonyl, according to the scene setting unattended automatic continuous work for a long time, depending on the complexity of the working condition of field test, optional corresponding pretreatment system, to ensure that the test results are accurate and reliable process, fully meet the requirements of different occasions.
 
This method is suitable for the hexavalent chromium in waste water within the scope of 0 ~ 30 mg/L, after preprocessing and adjust the measurement process Settings can also be very low and very high levels of total chromium, suitable for rapid analysis of rivers and lakes water, tap water, waste water, high concentration of sewage, and various of hexavalent chromium/total chromium content in the solution.
 
The performance characteristics of
Principle of mixer instrument detection using national standard method, test process completely in line with industry standards
Mixer simple maintenance, low operating cost
Convenient maintenance, low failure rate and long life
Mixer automatic calibration and cleaning
Pieces of data stored records will never be lost
Components and energy saving, no secondary pollution
Mixer automatic alarm, automatic diagnosis and automatic eliminate residual reactants and automatically return to work
 

Method of measurement

Diphenyl carbonyl 2 hydrazine spectrophotometric colorimetry

Measurement cycle

The minimum test cycle is 20min

Measuring range

0~30mg/L(expandable)

Sampling period

Time interval (adjustable), hour or trigger measurement mode can be set

resolution of the

0.001 mg/L

Calibration cycle

Automatic calibration (1~99 days adjustable), according to the actual water sample, manual calibration can be set

Accuracy of

Soil < 10% or < +0.1mg/L (the larger of the two)

Maintenance cycle

The maintenance interval is more than 1 month, about 30min each time

Repeatability

5% or 0.05mg/L

Reagent consumption

Generally less than 0.5 yuan/sample

Zero drift

≤土5

Man-machine operation

Touch screen display and command input

Span drift

≤土5%  

Input interface

Switch quantity

Detection limit

0.01 mg/L

Output interface

2 channel RS232 digital output, 1 channel 4~20mA analog output

Data is stored

No less than half a year data storage

Work environment

Indoor work, the recommended temperature is 5~28C, the humidity is less than 90% (no condensation)

Power supply requirements

AC220V soil 15%, 50~60Hz, 5A

Size

Height 1500X width 550X depth 465 (mm)

 