TGH-STP Automatic on-line monitor of total phosphorus water quality

Page view

TGH-STP Automatic on-line monitor of total phosphorus water quality

没有此类产品
Description

Instrument is introduced
 
TGH - STP total phosphorus of water quality on-line automatic monitor by using phosphorus molybdenum blue colorimetric method can according to the set unattended automatic continuous work for a long time, depending on the complexity of the working condition of field test, optional corresponding pretreatment system, to ensure that the test results are accurate and reliable process, fully meet the requirements of different occasions. This method is applicable to wastewater with total phosphorus within the range of 0~500mg/L. Most common ions do not interfere with the determination, but for some samples containing a large amount of organic matter, the measurement results may be low.
 
The performance characteristics of
 
The principle of instrument testing adopts the national standard method, and the testing process fully conforms to the relevant standards of the industry
 
Simple maintenance and low running cost
 
Convenient maintenance, low failure rate and long service life
 
Automatic calibration and cleaning
 
Data storage records are never lost; Energy saving, no secondary pollution
 
Automatic alarm, automatic diagnosis, automatic elimination of residual reactants and automatic recovery
 

Method of measurement

Phosphorus molybdenum blue spectrophotometric colorimetric method

Measurement cycle

Minimum test cycle 20 min, according to the environment, can be in 5 ~ 120 min change color any time

Measuring range

0~500mg/L (step0~6 mg/L、0~30mg/L 2~500 mg/L

Sampling period

Time interval (adjustable), hour or trigger measurement mode can be set

resolution of the

0.001 mg/L

Calibration cycle

Automatic calibration (1~99 days adjustable), according to the actual water sample, manual calibration can be set

Accuracy of

≤土10% or ≤土0.1mg/L

Maintenance cycle

The maintenance interval is more than 1 month, about 30min each time

Repeatability

≤5% or ≤0.1mg/L

Reagent consumption

Generally less than 0.5 yuan/sample

Zero drift

≤土5%

Man-machine operation

Touch screen display and command input

Span drift

≤土5%

Input interface

Switch quantity

Detection limit

0.02 mg/L

Output interface

2 channel RS232 digital output, 1 channel 4~20mA analog output

Data is stored

No less than half a year data storage

Work environment

Indoor work, the recommended temperature is 5~28C, the humidity is less than 90% (no condensation)

Power supply requirements

AC220V soil 15%, 50~60Hz, 5A

Size

Height 1500X width 550X depth 465 (mm)

 